- Response Time :
- Current Rating :
-
- 1 A (1)
- 1.2 kA (2)
- 1.275 kA (1)
- 1.7 A to 7.5 A (5)
- 100 A (5)
- 125 A (3)
- 150 A (8)
- 16 mA (1)
- 180 A (3)
- 19 mA (3)
- 20 mA (2)
- 200 A (7)
- 200 mA (1)
- 225 A (3)
- 235 A (1)
- 250 mA to 1 A (6)
- 36 A (6)
- 40 mA (1)
- 400 A (2)
- 43 A (1)
- 45 A (1)
- 5 A (3)
- 550 A (1)
- 56 A (2)
- 57 A (2)
- 60 A (1)
- 600 A (2)
- 625 A (1)
- 70 A (2)
- 72 A (3)
- 75 A (3)
- 765 A (1)
- 9 A (1)
- 90 A (6)
- 92 A (4)
- 950 A (1)
- Accuracy :
- Sensor Type :
100 產品
圖片 | 型號 | 價格 | 數量 | 庫存 | 製造商 | 描述 | Operating Supply Voltage | Response Time | Frequency Range | Current Rating | Accuracy | Sensor Type | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
獲得報價 |
43
有現貨
|
Honeywell | Board Mount Current Sensors 550A 6 Vdc to 12 Vdc Induc Ana Curnt Sens | 12 V | 3 us | - | 550 A | - | Open Loop | |||
|
獲得報價 |
108
有現貨
|
Honeywell | Board Mount Current Sensors 0.25-1.0A AC or DC current | 12 V | 100 us | - | 250 mA to 1 A | 0.5 % | Current Sense Monitor | |||
|
獲得報價 |
199
有現貨
|
Honeywell | Board Mount Current Sensors 1A 4.5Vdc to 10.5Vdc In-Cir Ana Curnt Se... | 10 V | 3 us | - | 1 A | 1.5 % | Open Loop | |||
|
獲得報價 |
134
有現貨
|
Honeywell | Board Mount Current Sensors clsd loop / MR tech. 25 amp-turns nominal | 5 V | 0.2 us | - | 56 A | 0.24 % | Closed Loop | |||
|
獲得報價 |
136
有現貨
|
Honeywell | Board Mount Current Sensors 57A Bottom Mnt. AC or DC current | 16 V | 3 us | - | 57 A | - | Open Loop | |||
|
獲得報價 |
41
有現貨
|
Honeywell | Board Mount Current Sensors +/-100A +/-0.5% Closed Loop Linear | 15 V | 1 us | - | 100 A | 0.5 % | Closed Loop | |||
|
獲得報價 |
28
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT TRANSDUCER offset pin 1... | 15 V | 0.5 us | - | 90 A | 0.5 % | Closed Loop | |||
|
獲得報價 |
99
有現貨
|
Honeywell | Board Mount Current Sensors 40mA 4.5Vdc- 10.5Vdc In-Cir Ana Curnt Se... | 10 V | 3 us | - | 40 mA | 1.5 % | Open Loop | |||
|
獲得報價 |
35
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT SENSORS | 15 V | 0.5 us | - | 150 A | 0.5 % | Closed Loop | |||
|
獲得報價 |
8
有現貨
|
Honeywell | Board Mount Current Sensors +/-1275 A +/-0.5 % Closed Loop Linear | 18 V | 1 us | - | 1.275 kA | 0.5 % | Closed Loop | |||
|
獲得報價 |
57
有現貨
|
Honeywell | Board Mount Current Sensors Linear Current Sensors 3-Pin | 16 V | 3 us | - | 19 mA | - | Open Loop | |||
|
獲得報價 |
34
有現貨
|
Honeywell | Board Mount Current Sensors Closed Loop 50A 1000 turn +/-70amp | 15 V | 1 us | - | 70 A | 0.5 % | Closed Loop | |||
|
獲得報價 |
24
有現貨
|
Honeywell | Board Mount Current Sensors 25A AC OR DC turns range 1000turn | 15 V | 1 us | - | 36 A | 0.5 % | Closed Loop | |||
|
獲得報價 |
6
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT SENSORS | 24 V | 1 us | - | 1.2 kA | 0.5 % | Closed Loop | |||
|
獲得報價 |
18
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT SENSORS | 15 V | 0.5 us | - | 180 A | 0.5 % | Closed Loop | |||
|
獲得報價 |
18
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT SENSOR | 10 V | 3 us | - | 5 A | 1.5 % | Open Loop | |||
|
獲得報價 |
20
有現貨
|
Honeywell | Board Mount Current Sensors 200mA 4.5Vdc-10.5Vdc In-Cir Ana Curnt Se... | 10 V | 3 us | - | 200 mA | 1.5 % | Open Loop | |||
|
獲得報價 |
10
有現貨
|
Honeywell | Board Mount Current Sensors +/-200 A +/-0.5 % Closed Loop Linear | 15 V | 0.5 us | - | 200 A | 0.5 % | Closed Loop | |||
|
獲得報價 |
29
有現貨
|
Honeywell | Board Mount Current Sensors 100A 4.5Vdcto10.5Vdc Induc Ana Curnt Sens | 10 V | 3 us | - | 100 A | - | Open Loop | |||
|
獲得報價 |
25
有現貨
|
Honeywell | Board Mount Current Sensors 125A Bottom Mnt. AC or DC current | 12 V | 3 us | - | 125 A | - | Open Loop | |||
|
獲得報價 |
7
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT SENSORS | 24 V | 1 us | - | 1.2 kA | 0.5 % | Closed Loop | |||
|
獲得報價 |
39
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT SENSORS | 15 V | 0.5 us | - | 150 A | 0.5 % | Closed Loop | |||
|
獲得報價 |
40
有現貨
|
Honeywell | Board Mount Current Sensors 235A sensed current sink/source output | 12 V | 3 us | - | 235 A | - | Open Loop | |||
|
獲得報價 |
58
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT SENSOR | 16 V | 3 us | - | 75 A | - | Open Loop | |||
|
獲得報價 |
36
有現貨
|
Honeywell | Board Mount Current Sensors 100A Bottom Mnt. AC or DC current | 16 V | 3 us | - | 100 A | - | Open Loop | |||
|
獲得報價 |
30
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT SENSORS | 12 V | 3 us | - | 400 A | - | Open Loop | |||
|
獲得報價 |
32
有現貨
|
Honeywell | Board Mount Current Sensors Linear Current Sens 3-Pin | 12 V | 3 us | - | 950 A | - | Open Loop | |||
|
獲得報價 |
45
有現貨
|
Honeywell | Board Mount Current Sensors 225A Bottom Mnt. AC or DC current | 16 V | 3 us | - | 225 A | - | Open Loop | |||
|
獲得報價 |
29
有現貨
|
Honeywell | Board Mount Current Sensors 6-12 VDC pin-out style 2 | 12 V | 3 us | - | 225 A | - | Open Loop | |||
|
獲得報價 |
38
有現貨
|
Honeywell | Board Mount Current Sensors CURRENT SENSORS | 15 V | 1 us | - | 90 A | 0.5 % | Closed Loop |